Tilt Switch Control, Model No. 21-38-4

$1,285.00
sold out

The Control Unit is housed in a NEMA 4 enclosure with large green (“Normal”) and red (“Alarm”) indicating lights on the front cover. A 0-10 second adjustable time delay circuit in the control unit prevents momentary tilting of the switch from causing a false or premature contact transfer. Two normally-open and two normally-closed output contacts are available for connection to external alarms and/or controls. Interruption of line power causes a relay transfer. (Also referred to as model 21-38-115)

This product meets CSA approvals for use in Normal and Hazardous Areas (rating of Class I, Divisions 1 and 2, Groups A, B, C, and D T2A, Class II, Division 1, Groups E, F, and G, Class II, Division 2, Groups F, and G Class III T160°C. Ta = 85°C max).

If shown as Sold Out, please contact for quote.

Add To Cart

The Control Unit is housed in a NEMA 4 enclosure with large green (“Normal”) and red (“Alarm”) indicating lights on the front cover. A 0-10 second adjustable time delay circuit in the control unit prevents momentary tilting of the switch from causing a false or premature contact transfer. Two normally-open and two normally-closed output contacts are available for connection to external alarms and/or controls. Interruption of line power causes a relay transfer. (Also referred to as model 21-38-115)

This product meets CSA approvals for use in Normal and Hazardous Areas (rating of Class I, Divisions 1 and 2, Groups A, B, C, and D T2A, Class II, Division 1, Groups E, F, and G, Class II, Division 2, Groups F, and G Class III T160°C. Ta = 85°C max).

If shown as Sold Out, please contact for quote.

The Control Unit is housed in a NEMA 4 enclosure with large green (“Normal”) and red (“Alarm”) indicating lights on the front cover. A 0-10 second adjustable time delay circuit in the control unit prevents momentary tilting of the switch from causing a false or premature contact transfer. Two normally-open and two normally-closed output contacts are available for connection to external alarms and/or controls. Interruption of line power causes a relay transfer. (Also referred to as model 21-38-115)

This product meets CSA approvals for use in Normal and Hazardous Areas (rating of Class I, Divisions 1 and 2, Groups A, B, C, and D T2A, Class II, Division 1, Groups E, F, and G, Class II, Division 2, Groups F, and G Class III T160°C. Ta = 85°C max).

If shown as Sold Out, please contact for quote.

 

Ramsey Steel Tilt Switch Control 21-38

Hazardous area Tilt Switch Controllers have cCSAus approval for Class II areas

Class II, III, Division 1, Groups #, F & G; Class II, III, Division 2, Groups F & G

Hazardous area probes MUST be used with hazardous area controls to be rated for hazardous areas.

Encloser Rating: NEMA 4

Power Requirements: 115 or 230 VAC versions, 50/60Hz +/- 10%

Outputs: One (1) DPDT contact. Rate at 10 Amp at 250 VAC or 7 Amp at 30 VDC, non-inductive

Time Delay: 0-10-23 seconds, adjustable

Circuitry Options: Select vertical or tilted probe position for “normal” condition

Rated for use in applications between -40°F to 140°F

Finish: Steel