Run-Off Switch, Model No. ROS-2E-3-4X-NPT

$888.00
sold out

This belt misalignment switch is used to monitor the position and tracking of conveyor belts. It is mounted on the conveyor structure and adjusted so the roller arm is the proper distance and angle from the outside edge of the belt. When a belt drifts out of alignment it contacts the roller actuator arm which rotates the actuation shaft, causing the belt misalignment switch to send an alarm signal.

This product meets CSA approvals for use in Normal and Hazardous Areas (rating of Class I, Divisions 1 and 2, Groups A, B, C, and D T2A, Class II, Division 1, Groups E, F, and G, Class II, Division 2, Groups F, and G Class III T160°C. Ta = 85°C max).

If shown as Sold Out, please contact for quote.

Add To Cart

This belt misalignment switch is used to monitor the position and tracking of conveyor belts. It is mounted on the conveyor structure and adjusted so the roller arm is the proper distance and angle from the outside edge of the belt. When a belt drifts out of alignment it contacts the roller actuator arm which rotates the actuation shaft, causing the belt misalignment switch to send an alarm signal.

This product meets CSA approvals for use in Normal and Hazardous Areas (rating of Class I, Divisions 1 and 2, Groups A, B, C, and D T2A, Class II, Division 1, Groups E, F, and G, Class II, Division 2, Groups F, and G Class III T160°C. Ta = 85°C max).

If shown as Sold Out, please contact for quote.

This belt misalignment switch is used to monitor the position and tracking of conveyor belts. It is mounted on the conveyor structure and adjusted so the roller arm is the proper distance and angle from the outside edge of the belt. When a belt drifts out of alignment it contacts the roller actuator arm which rotates the actuation shaft, causing the belt misalignment switch to send an alarm signal.

This product meets CSA approvals for use in Normal and Hazardous Areas (rating of Class I, Divisions 1 and 2, Groups A, B, C, and D T2A, Class II, Division 1, Groups E, F, and G, Class II, Division 2, Groups F, and G Class III T160°C. Ta = 85°C max).

If shown as Sold Out, please contact for quote.

 

Ramsey's Pro-Line Belt Misalignment Switch ROS-2E-3-4X-NPT

NEMA 4X Enclosure

cCSAus rated for Class II, Div 1 & 2, Group E, F & G applications

Rated for use in applications between -40° to +185° F (-40° to +85° C)

Actuator arm adjustments: 22.5 degree increments from vertical

Conduit Openings: Two threaded 3/4-14 NPT

Contacts: (2) SPDT switches

Contact rating: 10 Amps, 250 VAC

 
 

Resellers please contact us for bulk discounts.